Performance of screening mammography: A report of the alliance for breast cancer screening in Korea
- 1. Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of)
- 2. Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)
- 3. Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of)
Description
To analyze the diagnostic accuracy and trend in screening mammography in Korea. We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations
Additional details
Publishing Information
- Journal Title
- Korean Journal of Radiology
- Journal Volume
- 17
- Journal Issue
- 4
- Series
- 17 refs, 2 figs, 7 tabs
- Journal Page Range
- p. 489-496
- ISSN
- 1229-6929
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 47111483
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; DETECTION; DIAGNOSTIC TECHNIQUES; MAMMARY GLANDS; NEOPLASMS; PERFORMANCE; REPUBLIC OF KOREA; SCREENING; SENSITIVITY
- Descriptors DEC
- ASIA; BODY; DEVELOPING COUNTRIES; DISEASES; GLANDS; ORGANS