The development of a thin shell to act as the outer wall of a protection-level ionisation chamber is described. The optimisation of the energy-dependence of response of the chamber is outlined and the results are presented of tests to determine the long-term volume stability of the shell and the effects of temperature cycling and x and γ-irradiation. (author)
Additional details
Publishing Information
- Publisher
- Society for Radiological Protection.
- Imprint Place
- Berkeley (UK)
- ISBN
- 0 9508123 0 7
- Imprint Title
- Radiological protection - advances in theory and practice. Proceedings of the 3. international symposium held in Inverness, Scotland, 6-11 June 1982
- Imprint Pagination
- v. 2.
- Journal Page Range
- p. 451-456.
Conference
- Title
- 3. International symposium on radiological protection - advances in theory and practice.
- Dates
- 6 - 11 Jun 1982.
- Place
- Inverness, Scotland (UK).
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 14743200
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION STANDARDS; CARBON; ENERGY DEPENDENCE; EPOXIDES; FABRICATION; FIBERS; GAMMA RADIATION; IONIZATION CHAMBERS; SENSITIVITY; TEMPERATURE DEPENDENCE; X RADIATION
- Descriptors DEC
- ELECTROMAGNETIC RADIATION; ELEMENTS; IONIZING RADIATIONS; MEASURING INSTRUMENTS; NONMETALS; ORGANIC COMPOUNDS; ORGANIC OXYGEN COMPOUNDS; RADIATION DETECTORS; RADIATIONS