Evaluation of Eddy Current Signals from the Inner Wall Axial Cracks of Steam Generator Tubes

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
  • 2. KAITEC, Seoul (Korea, Republic of)

Description

For the enhancement of ECT reliability on the primary water stress corrosion cracks of nuclear steam generator tubes, of which the occurrence is on the increase, it is important to comprehend the signal characteristics on crack morphology and to select an appropriate probe type. In this paper, the sizing accuracy and the detectability for the inner wall axial cracks of tubes were quantitatively evaluated using the following specimens: the electric discharge machined notches and the corrosion cracks which were developed on the operating steam generator tubes. The difference of eddy current signal characteristics between pancake and axial coil were also Investigated. The results obtained from this study provide a useful information for more precise evaluation on the inner wall axial tracks oi steam generator tubes

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Nondestructive Testing
Journal Volume
21
Journal Issue
5
Series
12 refs, 11 figs, 2 tabs
Journal Page Range
p. 501-509
ISSN
1225-7842

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
42054468
Subject category
S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
CRACKS; EDDY CURRENTS; RELIABILITY; SIGNALS; STEAM GENERATORS; STRESS CORROSION; TUBES
Descriptors DEC
BOILERS; CHEMICAL REACTIONS; CORROSION; CURRENTS; ELECTRIC CURRENTS; VAPOR GENERATORS