Published April 1982
| Version v1
Report
Restricted
Field measurements and interpretation of TMI-2 instrumentation: NI-AMP-2
Description
Based on the limited measurements and the attempts to activate the high voltage power supply, the Source Range Monitor which includes NI-AMP-2 is not operating. Since there appears to be an excessive load on the high voltage, it appears that either the detector or cable is defective. However, TDR measurements did not indicate a significant problem with the cable using low level test signals
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01 as DE82013782.
Files
Additional details
Publishing Information
- Imprint Pagination
- 45 p.
- Report number
- GEND-INF--017-Vol.11
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14724053
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AMPLIFIERS; BF3 COUNTERS; FAILURES; REACTOR ACCIDENTS; REACTOR INSTRUMENTATION; THREE MILE ISLAND-2 REACTOR
- Descriptors DEC
- ACCIDENTS; ENRICHED URANIUM REACTORS; EQUIPMENT; MEASURING INSTRUMENTS; NEUTRON DETECTORS; POWER REACTORS; PROPORTIONAL COUNTERS; PWR TYPE REACTORS; RADIATION DETECTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS