Assessment of patient radiation doses in chest X-ray examinations
- 1. Milan Univ., (Italy). Ist. di Medicina del Lavoro
- 2. Ist. Clinici di Perfezionamento, Milan (Italy). Serv. di Radiologia e Radioterapia
Description
The paper reports the initial results of a radioprotection programme for diagnostic radiology carried out in a major hospital in Milan. The data cover chest X-ray examinations. The dose values were obtained using different techniques, according to the specific diagnostic requirements in each departement. A wide radiation dose range was observed between the different techniques, with a ratio between maximum and minimum dose > 30 for the skin and the spine. The doses were however lower than those capable of inducing non-stochastic effects by about 10000 and were so low that the probability of a stochastics effect is minimal. Nevertheless, because chest X-rays are performed so frequently, it is recommended that radiologists take greater account of patient dose, as far as compatible with diagnostic requirements. Radiology technicians must strictly observe the regulations for radioprotection of the patient
Additional details
Additional titles
- Original title (Italian)
- Esame radiologico al torace
- Original subtitle (Italian)
- Valutazione delle dosi somministrate al paziente.
Publishing Information
- Journal Title
- Med. Lav.
- Journal Volume
- 78
- Journal Issue
- 2
- Series
- Med. Lav.
- Journal Page Range
- 105-111
- ISSN
- 0025-7818
- CODEN
- MELAA
INIS
- Country of Publication
- Italy
- Country of Input or Organization
- Italy
- INIS RN
- 19012893
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- BIOLOGICAL RADIATION EFFECTS; BIOMEDICAL RADIOGRAPHY; CHEST; RADIATION DOSES; RADIATION PROTECTION; X-RAY RADIOGRAPHY
- Descriptors DEC
- BIOLOGICAL EFFECTS; BODY; BODY AREAS; DIAGNOSTIC TECHNIQUES; MEDICINE; RADIATION EFFECTS