Published August 2020 | Version v2
Journal article Open

Design and simulation analysis of mechanical system of reference network for alignment based on Hefei Advanced Lightsource Facility

  • 1. National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei (China)

Description

The accurate measurement and installation of magnet position and attitude in the new generation particle accelerator depends on the comprehensive use of various technologies. To achieve accurate positioning of magnets in the global coordinate system, and fast and precise installation and measurement, thus to build a fourth-generation synchrotron radiation source with high brightness and low emissivity, the National Synchrotron Radiation Laboratory researchers conducted a pre-research on the Hefei Advanced Lightsource Facility (HALF). As an important research content of alignment measurement system, a reference network for alignment (RNA) is proposed. To ensure the accuracy of the alignment measurement, the deformation requirements of the mechanical system of the RNA are very high. Therefore, we performed a static simulation of the entire mechanical system with ANSYS software, and optimized the alignment reference plate based on the analysis results to meet the requirements of working conditions, and laid a solid foundation for subsequent pre-research. (authors)

Files

CN2402959.pdf

Files (1.4 MB)

Name Size Download all
md5:9888aa11cf4938cef641b5c8c5d803a6
1.4 MB Preview Download

Additional details

Identifiers

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
32
Journal Issue
8
Journal Page Range
[7 p.]
ISSN
1001-4322

Optional Information

Notes
13 figs., 2 tabs., 10 refs.; http://dx.doi.org/10.11884/HPLPB202032.200003