Published June 1975 | Version v1
Report

Methods used to compensate the delay component of platinum self-powered detectors

  • 1. Hydro-Quebec, Montreal (Canada). Research Inst.

Description

Platinum self-powered detectors possess several desirable characteristics such as prompt response to power change, good sensitivity and low burnup. Platinum detectors, however, have a mixed neutron gamma response which poses problems in relating signal to power. The major drawback to the detector response is the delayed component, which is about 20% of the total signal. Two methods used to compensate for this component are described. One of these is feedforward compensation, in which the detector signal is passed through a filter (analog or digital) which has the inverse transfer function of the platinum detector. The other method is feedback compensation, in which the detector signal is made to agree, in long term, with a more accurate power measurement such as thermal measurements. (author)

Additional details

Publishing Information

Imprint Title
Proceedings of the IAEA specialists' meeting on in-core instrumentation and failed fuel detection and location, Mississauga, Ontario, Canada, May 13-15, 1974
Imprint Pagination
p. 159-172.
Report number
AECL--5124

Conference

Title
IAEA specialists' meeting on in-core instrumentation and failed fuel detection and location.
Dates
13 May 1974.
Place