Determining the boron concentration during long-term cooling of the reactor core after large loss of coolant accident

  • 1. Institut Jozef Stefan, Ljubljana (Yugoslavia)

Description

Critical boron concentration before and after postulated loss of coolant accident with long-term cooling recirculation was calculated for cycle 6 of Krsko NPP. The limiting boron concentration curve of containment sump was calculated for equilibrium conditions. The results were analysed and showed that the boron concentration in refueling water storage tank and in safety injection accumulators should be increased from 2000 to 2100 ppm in 6th cycle. In the consequence corresponding chapters of the NPP Krsko technical Specifications were changed as well. (author)

Availability note (English)

Available from INIS in electronic form; Also available from the Institute of Nuclear Sciences VINCA

Files

38013853.pdf

Files (311.8 kB)

Name Size Download all
md5:b9c9db8dd10c11278bde3164ba07f901
311.8 kB Preview Download

Additional details

Additional titles

Original title (Slovenian)
Dolocenje koncentracij bora pri dolgotrajnoem hladjenju sredice po veliki izlivni nezgodi

Publishing Information

Publisher
Society for Electronics,Telecommunications, Automation, and Nuclear Engineering
Imprint Place
Belgrade (Yugoslavia)
Imprint Pagination
8 p.
Report number
INIS-RS--0558

Conference

Title
Society for Electronics, Telecommunications, Computers, Automation, and Nuclear Engineering
Original Conference Title
ETAN '88: 32. Konferencija za elektroniku, telekomunikacije, automatiku i nuklearnu tehniku
Acronym
32. Conference - ETRAN '88
Dates
6-10 Jun 1988
Place
Sarajevo (Yugoslavia)

Optional Information

Notes
7 refs., 2 tabs., 1 figs.