Published October 1978 | Version v1
Report Open

LMFBR steam generator leak detection development in the United States

  • 1. General Electric Company, Sunnyvale, CA (United States)
  • 2. Argonne National Laboratory, Argonne, IL (United States)

Description

Leak detection for Liquid Metal Fast Breeder Reactor steam generators is an important economic factor in the shutdown, repair and restart of a plant. Development of leak detection systems in the U.S. has concentrated on four areas: (1) chemical (H2 and O2) leak detection meters; (2) acoustic leak detection/location techniques; (3) investigation of leak behavior (enlargement, damage effects, plugging and unplugging); and (4) data management for plant operations. This paper discusses the status, design aspects, and applications of leak detection technology for LMFBR plants. (author)

Files

33011350.pdf

Files (344.7 kB)

Name Size Download all
md5:cb6fae3ba3a1ae9313b898eb1879ed58
344.7 kB Preview Download
Part of:
Specialists meeting on leak detection and location in LMFBR steam generators. Summary report

Additional details

Publishing Information

Imprint Title
Specialists meeting on leak detection and location in LMFBR steam generators. Summary report
Imprint Pagination
144 p.
Journal Page Range
p. 108-119
Report number
IWGFR--25

Conference

Title
IAEA-IWGFR specialists meeting on leak detection and location in LMFBR steam generators
Dates
6-9 Jun 1978
Place
Dimitrovgrad (USSR)

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
33011350
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACOUSTIC DETECTION; LEAK DETECTORS; LMFBR TYPE REACTORS; MEASURING METHODS; REACTOR SHUTDOWN; STEAM GENERATORS
Descriptors DEC
ACOUSTIC MEASUREMENTS; BOILERS; BREEDER REACTORS; CHARGED PARTICLE DETECTION; DETECTION; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; LIQUID METAL COOLED REACTORS; RADIATION DETECTION; REACTORS; SHUTDOWN; VAPOR GENERATORS

Optional Information

Contract/Grant/Project number
Contract EY-76-C-03-893-10
Notes