Published July 2018 | Version v1
Journal article

Calibration of a permeameter for measuring soft magnetic materials using long cylindrical samples characterized by demagnetizing-corrected solenoid method

  • 1. Departament de Física, Universitat Autònoma de Barcelona, 08193 Bellaterra, Barcelona (Spain)
  • 2. Hunan Forever Elegance Technology, 417000 Loudi (China)
  • 3. Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska 9, 84104 Bratislava (Slovakia)

Description

A technique is developed to calibrate the performance of a permeameter for measuring soft magnetic materials, having a C-shaped magnetic potential H-coil near the sample surface and a B-coil surrounding the sample, by using cylindrical standard samples. The true M(H) curve for the standard samples of large length-to-diameter ratios is obtained by the demagnetizing-corrected solenoid method recently developed.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.jmmm.2018.02.088

Additional details

Identifiers

DOI
10.1016/j.jmmm.2018.02.088;
PII
S030488531830074X;

Publishing Information

Journal Title
Journal of Magnetism and Magnetic Materials
Journal Volume
458
Journal Page Range
p. 137-146
ISSN
0304-8853
CODEN
JMMMDC

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
53026666
Subject category
S36: MATERIALS SCIENCE;
Descriptors DEI
CALIBRATION; DIAGRAMS; MAGNETIC MATERIALS; PERFORMANCE; SOLENOIDS; SURFACES
Descriptors DEC
ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; INFORMATION; MATERIALS