The etch-induction time Ti and etch-critical time Tc in CR-39 plastic nuclear track detector

  • 1. Alexandria Univ. (Egypt). Dept. of Physics
  • 2. Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete
  • 3. Alexandria Univ. (Egypt). Biophysics Dept.

Description

The etch-induction time, Ti, is measured for α-particles in CR-39 plastic track detector and the etch-critical time, Tc, is calculated for α-particles in CR-39 detector as a function of α-energy and incident angle. The etch-induction time was found to be independent of dip angle and directly proportional to the α-particle energy in the range from 1-6.1 MeV. The etch-critical time was found to be zero for angles greater than the critical angle, θc, whereas at angles less than θc, the etch-induction time, Ti, was increased by the value of Tc. (orig.)

Abstract (German)

Die Induktionsaetzzeit Ti wurde fuer Alpha-Teilchen in einem CR-39 Plast-Kernspurdetektor gemessen und die kritische Aetzzeit Tc wurde fuer die Alpha-Teilchen als Funktion der Energie und des Einfallswinkels berechnet. Es wurde gefunden, dass die Induktionsaetzzeit unabhaengig vom Eintauchwinkel und direkt abhaengig von der Teilchenenergie im Bereich von 1-6.1 MeV ist. Die kritische Aetzzeit war Null fuer Winkel, die groesser als der kritische Winkel θc waren, waehrend fuer Winkel, die kleiner als θc waren, die Induktionsaetzzeit Ti zunahm bis zum Wert von Tc. (orig.)