Design, development and testing of real time control and data acquisition system for R&D IC H&CD source

  • 1. ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India)
  • 2. Optimized Solutions Pvt. Ltd., Ahmedabad, Gujarat (India)

Description

Highlights: • Application program of LCU is developed using LabVIEW™ to operate megawatt RF source. • PXI 6133 module is used for acquiring data with 1 MHz sampling frequency in trigger mode. • PXI 6255 is used for continuous acquisition with 1 KHz sampling frequency. • PXI 7841 R is used for hard wired fast protection function and for real time control loop. • Schneider PLC is used to develop sequence control system. - Abstract: One of the important auxiliary heating and current drive systems for ITER experiment is Ion Cyclotron Heating & Current Drive (IC H&CD) system. ITER requires 1 prototype and 8 independent RF Sources, each having capability to deliver constant output power of 2.5 MW at VSWR 2 in the frequency range of 35–65 MHz. To meet the ITER requirement, an R&D program has been launched to identify the final stage tube (Tetrode/Diacrode) for MW level RF amplifier, along with other critical components. Under this R&D program, single chain of RF cascaded amplifiers, consisting of low & high power RF sections, auxiliary power supply, Anode power supply and test bench simulating ITER requirement, are being developed. To ensure reliable and safe operation of the entire system, PLC/PXI based Local Control Unit (LCU) is developed. PLC based sequential control system is developed for sequential biasing of electrodes of high power vacuum tubes (Tetrode/Diacrode). To protect the RF Source against critical fault condition, local protection logic is developed using PXI-7841R, which will ensure fast shut off (<10 μs) of RF and power supplies. Constant and stable power output even with variable load condition (up to VSWR 2) is achieved by employing two real time feedback control loops-one for making constant output power and the other one for optimizing anode & screen grid dissipation. For fault/offline analysis, event based acquisition and logging functionality is provided that acquires and logs data at 1 μs sampling rate for 100 ms pre and post time. During the RF Shot, normal acquisition and logging for all channels are provided with 1 ms sampling rate. Further, online display for user selectable 8 channels is provided. All the operational and monitoring parameters are continuously updated on Main screen to give the real time status of the system. In this paper, salient feature of R&D LCU and test results are discussed in detail.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.fusengdes.2016.05.029

Additional details

Identifiers

DOI
10.1016/j.fusengdes.2016.05.029;
PII
S0920-3796(16)30386-6;

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
112
Journal Page Range
p. 752-756
ISSN
0920-3796
CODEN
FEDEEE

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.