Recirculating steam generator operation at very low power

  • 1. FRAMATOME, 92 - Paris-La-Defence (France)

Description

The behaviour of recirculating SG's at very low power has been thoroughly investigated by laboratory and on-site tests as well as numerical simulations. A special experimental program dedicated to recirculation threshold determination has been performed on the Freon SG mock-up CLOTAIRE. These laboratory data are completed with transients of feedwater injections at hot stand-by on two instrumented SG's, one boiler type SG and one economizer type SG. The phenomena are different on both types. In boiler SG's, the SG behaves like a U-tube and recirculation stops around 2% load at stand-by temperature and water level. In economizer SG's, the presence of 2 separate down-comers and a divider plate inside the tube bundle allows a recirculation loop by-passing the separators. The mixing of saturated and cold water induced by this loop limits down-comer cooling and thus alleviates the thermal load on the tube sheet. These tests were used to validate the SG transient analysis 1-D code ANETH. (author)

Availability note (English)

Available from INIS in electronic form

Files

33003459.pdf

Files (380.1 kB)

Name Size Download all
md5:ad11ae6cfa2eb93b2de16bd7331647e3
380.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
[21 p.]
Report number
INIS-FR--511

Conference

Title
9. international conference on nuclear engineering
Dates
8-12 Apr 2001
Place
Nice, Acropolis (France)

Optional Information

Notes
8 refs.