Published 2010 | Version v1
Book

Overpressure protection system for moisture separator reheater

  • 1. Mitsubishi Heavy Industries, LTD., 2-1-1, Shinhama, Arai, Takasago (Japan)

Description

Highly reliable over pressure protection system for moisture separator reheater (MSR) is developed which prevents MSR shell from over pressure by function to tripping the turbine when the shell pressure increases up to the set point. The maximum design pressure of MSR is nearly equal to that of current design by suitably selecting the set point pressure of the protection system. The system could eliminate numerous numbers of large capacity relief valves, their main pipes and succeeding periodical maintenance works such as disassembly and function test, without failing unit reliability and availability. (authors)

Part of:
Proceedings of the 2010 International Congress on Advances in Nuclear Power Plants - ICAPP '10

Additional details

Publishing Information

Publisher
American Nuclear Society - ANS
Imprint Place
La Grange Park (United States)
ISBN
978-89448-081-2
Imprint Title
Proceedings of the 2010 International Congress on Advances in Nuclear Power Plants - ICAPP '10
Imprint Pagination
2284 p.
Journal Page Range
p. 868-874

Conference

Title
2010 International Congress on Advances in Nuclear Power Plants
Acronym
ICAPP '10
Dates
13-17 Jun 2010
Place
San Diego, CA (United States)

INIS

Country of Publication
United States
Country of Input or Organization
France
INIS RN
42099935
Subject category
S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AVAILABILITY; DESIGN; MAINTENANCE; MOISTURE; PIPES; PRESSURE CONTROL; RELIABILITY; RELIEF VALVES; SAFETY; SHELLS; TURBINES; VAPOR SEPARATORS
Descriptors DEC
CONTROL; CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; MACHINERY; SEPARATION EQUIPMENT; TUBES; TURBOMACHINERY; VALVES

Optional Information