Published June 23, 2006 | Version v1
Journal article

The Linac coherent light source at SLAC. Radiological considerations and shielding calculations

  • 1. Stanford Linear Accelerator Center (SLAC), Menlo Park, CA 94022 (United States)

Description

The Linac Coherent Light Source (LCLS) at SLAC will be the world's first X-ray free electron laser when it becomes operational in 2009. Pulses of X-ray laser light from LCLS will be many orders of magnitude brighter and several orders of magnitude shorter than what can be produced by other X-ray sources available in the world. These characteristics will enable frontier new science in many areas. This paper describes the LCLS beam parameters and its lay-out. Results of the Monte Carlo calculations for the shielding design of the electron dump line, radiation damage to undulator, the residual radiation and the soil activation around the electron dump are presented

Additional details

Identifiers

DOI
10.1016/j.nima.2006.02.115;
PII
S0168-9002(06)00391-3;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
562
Journal Issue
2
Journal Page Range
p. 958-962
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
7. international conference on accelerator applications
Acronym
AccApp05
Dates
28 Aug - 1 Sep 2005
Place
Venice (Italy)

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.