Published October 15, 1976 | Version v1
Journal article

An external muon identifier for the Fermilab 15 ft bubble chamber

  • 1. Hawaii Univ., Honolulu (USA)
  • 2. California Univ., Berkeley (USA). Lawrence Berkeley Lab.

Description

An external muon identifier to aid in the identification of muons produced in neutrino interactions in the Fermilab 15 ft bubble chamber has been constructed. Details of design and analysis procedures are discussed. The spatial resolution and efficiency have been calibrated using muons regenerated by neutrino interactions in material upstream of the bubble chamber. A formalism to describe the statistical significance of muon matches in the identifier is developed and tested using tracks from actual neutrino interactions. (Auth.)

Additional details

Identifiers

Publishing Information

Journal Title
Nuclear Instruments and Methods
Journal Volume
138
Journal Issue
2
Series
Nucl. Instrum. Methods.
Journal Page Range
245-254
ISSN
0029-554X

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent