Published March 1976 | Version v1
Journal article

Simultaneous determination of trace niobium, tantalum and tungsten in ferrous and non-ferrous alloys

  • 1. Colt Industries Crucible Inc., Materials Research Center, Pittsburgh, Pa. (USA)

Description

A method is presented for the determination of niobium, tantalum and tungsten in steel and non-ferrous alloys, based on hydrolysis with sulphurous acid followed by X-ray fluorescence measurements. The limit of determination is about 0.002% and the standard deviation is 0.002 at the 0.05% level. Results below 0.01% by this method are only semiquantitative. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Talanta
Journal Volume
23
Journal Issue
3
Series
Talanta.
Journal Page Range
225-228
ISSN
0039-9140

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent