Published 2005 | Version v1
Miscellaneous

Development of a highly sensitive current and position monitor with HTS squids and an HTS magnetic shield

  • 1. RIKEN, Wako, Saitama (Japan)
  • 2. Tokyo Univ., Center for Nuclear Study, Wako, Saitama (Japan)
  • 3. Matsushita Electric Industrial, Osaka (Japan)
  • 4. KT Science Ltd., Kakogawa, Hyogo (Japan)

Description

A highly sensitive current and position monitor with HTS (High-Temperature Superconducting) SQUIDs (Superconducting QUantum Interference Device) and an HTS magnetic shield for the measurement of the intensity of faint beams, such as a radioisotope beam, has been developed for the RIKEN RI beam factory project. The HTS magnetic shield and the HTS current sensor including the HTS SQUID are cooled by a low-vibration pulse-tube refrigerator. Both the HTS magnetic shield and the HTS current sensor were fabricated by dip-coating a thin Bi2-Sr2-Ca2-Cu3-Ox (Bi-2223) layer on 99.9% MgO ceramic substrates. The HTS technology enables us to develop a system equipped with a downsized and highly sensitive current monitor. Recently, a prototype system was completed and installed in the beam transport line of the RIKEN Ring Cyclotron to measure the DC-current of high-energy heavy-ion beams. As a result, we succeeded in measuring the intensity of the 600 nA 40Ar17+ beam (95 MeV/u). We describe the present status of the monitor system and the results of the beam measurements. (author)

Part of:
Cyclotrons and their applications 2004. Proceedings of the seventeenth international conference

Additional details

Publishing Information

Imprint Title
Cyclotrons and their applications 2004. Proceedings of the seventeenth international conference
Imprint Pagination
707 p.
Journal Page Range
p. 401-403

Conference

Title
17. international conference on cyclotrons and their applications 2004
Dates
18-22 Oct 2004
Place
Tokyo (Japan)

Optional Information

Notes
7 refs., 7 figs., 1 tab.