Published 1996
| Version v1
Journal article
The measurement of aerosol size distributions (AMAD) in buildings on BNFL's Sellafield site
Description
Cascade centripeters were used to make measurements of aerosol activity size distributions in several buildings involved in the reprocessing of Magnox Nuclear Reactor Fuel on BNFL's Sellafield site. Whilst the 50 measurements made demonstrate significant variations in size distribution between buildings (2.8 μm-4.2 μm) and even between sampling locations within particular buildings (1.9 μm-9.0 μm), they demonstrate consistently larger particle sizes than the 1 μm AMAD default value recommended in ICRP Publication 30 and provide further empirical support for the adoption of a 5 μm AMAD default value as most recently proposed in ICRP Publication 66 for workplaces. (Author)
Additional details
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 63
- Journal Issue
- 2
- Journal Page Range
- p. 127-131.
- ISSN
- 0144-8420
- CODEN
- RPDODE
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 27047281
- Subject category
- S54: ENVIRONMENTAL SCIENCES; S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Descriptors DEI
- BNFL; BUILDINGS; PARTICLE SIZE; RADIATION MONITORING; RADIOACTIVE AEROSOLS; SELLAFIELD REPROCESSING PLANT
- Descriptors DEC
- AEROSOLS; COLLOIDS; DISPERSIONS; FUEL REPROCESSING PLANTS; MONITORING; NATIONAL ORGANIZATIONS; NUCLEAR FACILITIES; SIZE; SOLS; UNITED KINGDOM ORGANIZATIONS