Published October 2010 | Version v1
Miscellaneous Open

MCU calculation of spacing grid influence on fuel assembly axial power distribution

  • 1. RRC Kurchatov Institute, Moscow (Russian Federation)

Description

Presence of spacing grid in fuel assembly noticeably decreases local energy release due to small local change of uranium-water ratio. Condition of total energy release conservation leads to some increase in maximum of axial power distribution. With MCU Monte Carlo code these increase/decrease were calculated for some VVER-440 and VVER-1000 F As. Since geometry of spacing grid is very complicated, two different sensibly simplified models were proposed. Both gave close results. Local minimums turn out to be ∼5% lower than average and local maximums increase slightly more than 1%. (Authors)

Files

41131402.pdf

Files (303.3 kB)

Name Size Download all
md5:9471c849a1b18e4afb60367439fd0774
303.3 kB Preview Download
Part of:
Proceedings of the twentieth symposium of atomic energy research

Additional details

Publishing Information

Publisher
Kiadja and KFKI Atomenergia Kutatointezet
Imprint Place
Budapest (Hungary)
ISBN
978-963-372-643-3 (OE)
Imprint Title
Proceedings of the twentieth symposium of atomic energy research
Imprint Pagination
790 p.
Journal Page Range
p. 1-5
Report number
INIS-SK--2010-097

Conference

Title
20. Atomic Energy Research Symposium on WWER Physics and Reactor Safety
Dates
20-24 Sep 2010
Place
Hanasaari, Espoo (Finland)

Optional Information

Notes
3 figs.; 3 tabs.; 1 ref.