Published December 1983
| Version v1
Report
Restricted
Sequoyah Unit 1 charge converter examination results
Description
The accident at Three Mile Island subjected loose parts monitoring system charge converters to moderate levels of radiation that caused them to fail. Two charge converters exhibiting similar failure symptoms were removed from an operating plant, Sequoyah Unit 1, and examined to determine their failure modes and to estimate the total radiation doses received by each. Radiation degradation of the circuit was found to be highly dependent on the value of a select resistor
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE84005879.
Files
Additional details
Publishing Information
- Imprint Pagination
- 15 p.
- Report number
- SAND--83-1682
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15047210
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- FAILURES; LOOSE PARTS MONITORING; RADIATION DOSES; SEQUOYAH-1 REACTOR
- Descriptors DEC
- ENRICHED URANIUM REACTORS; MONITORING; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS