Published 2001
| Version v1
Miscellaneous
Reliability assessment of ultrasonic nondestructive inspection on piping in NPP - The result of PD-RR test (Part I)
Creators
- 1. Seoul National Univ., of Technology, Seoul (Korea, Republic of)
- 2. Hanyang Univ., Seoul (Korea, Republic of)
- 3. KINS, Taejon (Korea, Republic of)
Description
The performance demonstration round robin test was conducted to quantify the capability of ultrasonic inspection for in-service and to address some aspects of reliability for nondestructive evaluation. The fifteen inspection teams who employed procedures that met or exceeded ASME Sec. XI code requirements detected the piping of nuclear power plant with various cracks to evaluate the capability of detection, With data from PD-RR test, the performance of ultrasonic nondestructive inspection could be assessed using probability of detection and length and depth sizing of cracks
Additional details
Publishing Information
- Publisher
- KSME
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the KSME 2001 fall annual meeting A
- Imprint Pagination
- 881 p.
- Journal Page Range
- p. 246-251
Conference
- Title
- KSME 2001 fall annual meeting A
- Dates
- 1-3 Nov 2001
- Place
- Jeonju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 35102629
- Subject category
- S36: MATERIALS SCIENCE; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CRACKS; FRACTURE MECHANICS; NONDESTRUCTIVE ANALYSIS; NUCLEAR POWER PLANTS; RELIABILITY; RISK ASSESSMENT; THERMAL FATIGUE; ULTRASONIC TESTING; WELDING
- Descriptors DEC
- ACOUSTIC TESTING; CHEMICAL ANALYSIS; FABRICATION; FATIGUE; JOINING; MATERIALS TESTING; MECHANICAL PROPERTIES; MECHANICS; NONDESTRUCTIVE TESTING; NUCLEAR FACILITIES; POWER PLANTS; TESTING; THERMAL POWER PLANTS
Optional Information
- Notes
- 15 refs, 3 figs, 6 tabs