Published September 1996 | Version v1
Journal article

Treatment of High-Flow Vascular Malformations by Venous Embolization Aided by Flow Occlusion Techniques

  • 1. Department of Diagnostic Radiology, Royal Postgraduate Medical School, Hammersmith Hospital, Du Cane Road, London W12 OHS (United Kingdom)
  • 2. Department of Surgery, St. Mary's Hospital, Praed Street, London W2 (United Kingdom)

Description

Purpose: Transvenous embolization techniques may be helpful as alternatives to the arterial route when treating high-flow vascular malformations. We present our experience using these techniques in four patients. Methods: In one patient the venous portion of the arteriovenous malformation (AVM) was punctured directly; in the other three patients it was catheterized via a retrograde venous approach. Flow occlusion techniques were utilized in all patients during embolization, which was performed with absolute alcohol or N-butyl-2-cyanoacrylate.Results: Excellent clinical and angiographic results were obtained, with obliteration of arteriovenous shunting in all patients. There were no complications.Conclusion: The embolization of certain AVMs using a venous approach is a safe and effective treatment

Additional details

Identifiers

Publishing Information

Journal Title
Cardiovascular and Interventional Radiology
Journal Volume
19
Journal Issue
5
Journal Page Range
p. 323-328
ISSN
0174-1551
CODEN
CAIRDG

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
39093173
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALCOHOLS; BLOOD FLOW; EMBOLI; MALFORMATIONS; PATIENTS; VASCULAR DISEASES
Descriptors DEC
DISEASES; HYDROXY COMPOUNDS; ORGANIC COMPOUNDS; PATHOLOGICAL CHANGES

Optional Information

Copyright
Copyright (c) 1996 Springer-Verlag New York Inc.