Smears for determinations surface unfixed tritium contamination

  • 1. Horia Hulubei National Institute of Research and Development for Physics and Nuclear Energy, PO Box MG-6, 407 Atomistilor Street, Magurele (RO)

Description

The present paper describes a method of obtaining expanded polystyrene with hydrophilized surface smears by radioinduced grafting of acrylic acid. The grafting was carried out by using a 60 Co γ radiation source. The variation of grafting rates as a function of dose range and absorbed dose was established. Grafting radiochemical rates were determined by radiometric methods using acrylic acid labeled with tritium as a grafting agent. The sampling coefficients and the reproducibility were analyzed as a function of the nature of the contaminated surface. (authors)

Availability note (English)

Available from author(s) or National Institute of Research-Development for Cryogenics and Isotopic Technologies, ICSI, PO Box 10, Str. Uzinei nr. 4, RO-1000 Rm. Valcea (RO)
Part of:
The 9-th ICSI Conference 'Progress in Cryogenics and Isotope Separation'. Proceedings

Additional details

Additional titles

Original title (Romanian)
Frotiuri de prelevare contaminare de suprafata nefixata cu tritiu

Publishing Information

Publisher
National Institute of Research-Development for Cryogenics and Isotopic Technologies
Imprint Place
Caciulata (Romania)
Imprint Title
The 9-th ICSI Conference 'Progress in Cryogenics and Isotope Separation'. Proceedings
Imprint Pagination
208 p.
Journal Page Range
p. 138-141
ISSN
1582-2575

Conference

Title
9. ICSI conference 'Progress in Cryogenics and Isotope Separation'
Dates
17-18 Oct 2003
Place
Caciulata (Romania)

Optional Information

Notes
5 refs., 3 tabs.