Quantitative assessment of an increase of myocardial 99mTc-MIBI accumulation during exercise. Usefulness of response rate
Creators
- 1. Yamagata Univ. (Japan). School of Medicine
Description
The increase of myocardial 99mTc-MIBI accumulation during exercise was evaluated quantitatively, and the feasibility of response rate as a noninvasive marker of coronary stenosis was tested. Myocardial perfusion imaging with 99mTc-MIBI during exercise and at rest was performed in patients with suspected coronary artery disease. A dose of 296 MBq 99mTc-MIBI was injected intravenously at maximal treadmill exercise, and myocardial image was obtained 90 min later (1st image). Then, 740 MBq of 99mTc-MIBI was administered at rest, and myocardial image was repeated (2nd image). These images were corrected for a decay and injected dose, and the 1st image was subtracted from the 2nd image to obtain the rest image. An increase of myocardial accumulation of 99mTc-MIBI during exercise was defined as (exercise image-rest image) x 100/rest image (response rate). A response rate of a patient with normal coronary artery was 102%, whereas a response rate in the area of severe coronary stenosis was 21% in a patients with angina pectoris. After successful PTCA to a stenosed coronary artery, a response rate increased to 75% in this patient. Coronary perfusion reserve during exercise can be assessed noninvasively by 99MTc-MIBI. Response rate of 99mTc-MIBI provides additional information to conventional perfusion imaging and may be a new marker of severity of coronary artery disease. (author)
Additional details
Publishing Information
- Journal Title
- Kaku Igaku
- Journal Volume
- 33
- Journal Issue
- 7
- Journal Page Range
- p. 779-784.
- ISSN
- 0022-7854
- CODEN
- KAIGBZ
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 28021387
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOLOGICAL STRESS; CARDIOVASCULAR DISEASES; EXERCISE; ISONITRILES; MYOCARDIUM; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TECHNETIUM 99; UPTAKE; WASHOUT
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CARBONIC ACID DERIVATIVES; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DISEASES; EMISSION COMPUTED TOMOGRAPHY; FALLOUT; HEART; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MUSCLES; NUCLEI; ODD-EVEN NUCLEI; ORGANIC COMPOUNDS; ORGANS; RADIOISOTOPES; TECHNETIUM ISOTOPES; TOMOGRAPHY; YEARS LIVING RADIOISOTOPES