Calibration of secondary emission monitors of absolute proton beam intensity in the CERN SPS north area
Description
Secondary Emission Monitors (SEMs) are used at the SPS for measurements of the absolute proton beam intensity. As an accurate measurement was recently required by the NA56 (SPY) experiment, the responses of all the SEMs used in the SPS North Area, including those used for NA56, were calibrated. The independent measurement of the absolute proton intensity needed for this calibration was obtained by an activation method, where the radioactivity induced in a thin aluminium foil is measured with a gamma counter immediately after a short exposure of the foil to the proton beam. The foil activity was in turn calibrated using the absolute proton intensity measurements provided by the Beam Current Transformers (BCTs) available in the West Area Neutrino Facility. A description of the experimental method and results of the calibration are given. SEM calibration factors were determined with an error that, even in the worst case, does not exceed 3%. The response per unit proton intensity of the new titanium SEMs installed in 1995 is about 9% smaller than that of the traditional aluminium SEMs. The measured calibration factor of the titanium monitor used by NA56 has been shown to be stable within ±1% over a period of almost one month. By combining this additional uncertainty to the error on the determination of the calibration factor from the activation measurement, the absolute proton intensity delivered to NA56 could be measured with an uncertainty of 1.7%. (orig.)
Availability note (English)
Available from INIS in electronic formFiles
30002736.pdf
Files
(381.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:616e1e324ba34612b0b94cded6165244
|
381.9 kB | Preview Download |
Additional details
Publishing Information
- ISBN
- 92-9083-119-7
- Imprint Pagination
- 25 p.
- ISSN
- 0007-8328
- Report number
- CERN--97-07
INIS
- Country of Publication
- European Organization for Nuclear Research (CERN)
- Country of Input or Organization
- European Organization for Nuclear Research (CERN)
- INIS RN
- 30002736
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; BEAM CURRENTS; BEAM MONITORS; CALIBRATION; CERN SPS SYNCHROTRON; PROTON BEAMS; RESPONSE FUNCTIONS; SECONDARY EMISSION DETECTORS
- Descriptors DEC
- ACCELERATORS; BEAMS; CURRENTS; CYCLIC ACCELERATORS; FUNCTIONS; MEASURING INSTRUMENTS; MONITORS; NUCLEON BEAMS; PARTICLE BEAMS; RADIATION DETECTORS; SYNCHROTRONS