MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience
Creators
- 1. Medical University of Vienna (AKH), Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria)
- 2. Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)
Description
The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients underwent 487 MR-guided VABB using three different 8-10-gauge-VABB devices (Atec-9-gauge,A; Mammotome-8-gauge,M; Vacora-10-gauge,V). VABB data (lesion-type, size, biopsy device, histopathology) were compared to final diagnosis (surgery, n = 210 and follow-up, n = 277). Chi-square, and Kruskal-Wallis tests were applied. P values < 0.05 were considered significant. Final diagnosis was malignant in 104 (21.4 %), high risk in 64 (13.1 %) and benign in 319 (65.5 %) cases. Eleven of 328 (3.4 %) benign-rated lesions were false-negative (1/95, 1.1 %, A; 2/73, 2.7 %, M; 8/160 5.0 % V; P = 0.095). Eleven high-risk (11/77, 14.3 %) lesions proved to be malignant (3/26, 11.5 % A; 4/12, 33.3 % M; 4/39, 10.3 % V; P = 0.228). Five of 34 (14.7 %) DCIS were upgraded to invasive cancer (2/15, 13.3 %, A; 1/6, 16.6 % M; 2/13, 15.3 %, V; P = 0.977). Lesion size (P = 0.05) and type (mass vs. non-mass, P = 0.107) did not differ significantly. MR-guided VABB is an accurate method for diagnosis of MRI-only lesions. No significant differences on false-negative and underestimation rates were observed between three different biopsy devices. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-016-4267-9Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 26
- Journal Issue
- 11
- Journal Page Range
- p. 3908-3916
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48000295
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOPSY; CARCINOMAS; DIAGNOSIS; HISTOLOGY; IMAGE PROCESSING; MAMMARY GLANDS; NMR IMAGING; PATHOLOGICAL CHANGES; RELAXATION TIME; SENSITIVITY; SPECIFICITY; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; FUNCTIONS; GLANDS; NEOPLASMS; ORGANS; PROCESSING