Effects of irradiation conditions and environment on the reflectivity of different steel mirrors for ITER diagnostics systems

  • 1. Euratom/CIEMAT Fusion Association, Avenida Complutense 22, 28040 Madrid (Spain)

Description

In this work possible degradation of the reflectivity for mirrors made from various steels subjected to ionizing radiation, at moderate temperature and in different environments (vacuum, air, or nitrogen) up to a total dose of 9 MGy, has been examined. Mirrors were prepared from conventional austenitic stainless steel (316L) and also reduced activation ferritic/martensitic (RAFM) steels (Eurofer, ODS-Eurofer, F82H), and the reflectivity studied from ultraviolet to near infrared, before and after different treatments. Under all conditions the austenitic steel mirrors only degrade slightly (<10%), however for the reduced activation steels important reflectivity degradation for wavelengths below 1000 nm are observed for the different conditions. Surface morphology and microstructure has been also investigated using scanning electron microscopy (SEM). The production of near surface nitrides is considered to be the possible cause of the optical degradation.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.fusengdes.2008.12.067

Additional details

Identifiers

DOI
10.1016/j.fusengdes.2008.12.067;
PII
S0920-3796(08)00525-5;

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
84
Journal Issue
2-6
Journal Page Range
p. 935-938
ISSN
0920-3796
CODEN
FEDEEE

Conference

Title
25. symposium on fusion technology
Acronym
SOFT-25
Dates
15-19 Sep 2008
Place
Rostock (Germany)

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.