Published May 2011
| Version v1
Miscellaneous
MARS-KS Calculations for ATLAS 6-inch Cold Leg Break Test (DSP-02)
- 1. Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)
Description
An integral effect test on the SBLOCA (Small-Break Loss of Coolant Accident) aiming at 6-inch cold leg bottom break, SB-CL-09, was conducted with the ATLAS on November 13, 2009 by KAERI. The 6-inch cold leg SBLOCA test was selected for the second domestic standard problem (DSP-02) in 2010 to enhance the understanding on the behavior of nuclear reactor systems with the DVI and to assess existing and new thermalhydraulic analysis such as MARS, TRACE, RELAP, and so on. In this study, the calculations and analysis using MARS-KS V1.2 code were conducted for this 6-inch cold leg break test
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2011 spring meeting of the KNS
- Dates
- 26-27 May 2011
- Place
- Taebaek (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42099131
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPUTER CALCULATIONS; LOSS OF COOLANT; M CODES; PWR TYPE REACTORS; THERMAL HYDRAULICS
- Descriptors DEC
- ACCIDENTS; COMPUTER CODES; ENRICHED URANIUM REACTORS; FLUID MECHANICS; HYDRAULICS; MECHANICS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 2 refs, 5 figs, 2 tabs