Assessment of dynamic testing of shutdown systems at KAPS
Creators
- 1. Atomic Energy Regulatory Board, Bombay (India)
Description
During the initial commissioning of Kakrapar Atomic Power Station No.1, dynamic testing of shutdown systems, primary and secondary, (PSS and SSS) was carried out as part of the low power physics (Phase-B) measurements. The worth, reactivity insertion timings and the initial actuation delays are the important inputs for analyses of the results of dynamic testing of shutdown systems. The results of the experiments have been analysed using a computer code HYDRAX. The present paper brings out the comparison between calculated and measured values in the dynamic testing of shutdown systems and the accuracies of the design predictions against measurements. (author). 2 tabs., 4 figs
Additional details
Publishing Information
- Publisher
- Allied Publishers Limited.
- Imprint Place
- New Delhi (India)
- ISBN
- 81-7023-541-3
- Imprint Title
- National conference on radiation shielding and protection (RASP-96): Proceedings
- Imprint Pagination
- 321 p.
- Journal Page Range
- p. 144-148.
Conference
- Title
- national conference on radiation shielding and protection.
- Acronym
- RASP-96
- Dates
- 26-28 Jun 1996.
- Place
- Kalpakkam (India).
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 28021705
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- H CODES; KAKRAPAR-1 REACTOR; NEUTRON ABSORBERS; PERFORMANCE TESTING; REACTIVITY; REACTOR CONTROL SYSTEMS; REACTOR SHUTDOWN
- Descriptors DEC
- CANDU TYPE REACTORS; COMPUTER CODES; CONTROL SYSTEMS; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; NATURAL URANIUM REACTORS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; SHUTDOWN; TESTING; THERMAL REACTORS