Type tests to the automatic system of thermoluminescent dosimetry acquired by the CPHR for personnel dosimetry
Creators
- Molina P, D.1
- Pernas S, R.1
- Universidad Autonoma Metropolitana, Unidad Iztapalapa, Mexico D.F. (Mexico)
- Universidad Autonoma de Zacatecas (Mexico)
- Instituto Politecnico Nacional (Mexico)
- Consejo Zacatecano de Ciencia y Tecnologia, Zacatecas (Mexico)
- Gobierno del Estado de Zacatecas 2004-2010 (Mexico)
- CONACYT, Mexico D.F. (Mexico)
- 1. Centro de Proteccion e Higiene de las Radiaciones (CPHR), Calle 20, No. 4113 e/ 41 y 47, Miramar, Ciudad de la Habana (Cuba)
Description
The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF: Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)
Availability note (English)
Available from INIS in electronic formFiles
36105115.pdf
Files
(127.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:1a16bd34e2c3d0d06fd96eebfcde8683
|
127.4 kB | Preview Download |
Additional details
Additional titles
- Original title (Spanish)
- Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- INIS-MX--1907
Conference
- Title
- 8. International Conference; 18. National Congress on Solid State Dosimetry
- Dates
- 7-9 Sep 2005
- Place
- Zacatecas (Mexico)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 36105115
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- AUTOMATION; CESIUM 137; CHINA; COBALT 60; CUBA; DIAGRAMS; ENERGY DEPENDENCE; EXPERIMENTAL DATA; FINLAND; GAMMA RADIATION; KEV RANGE; PERSONNEL DOSIMETRY; TEMPERATURE DEPENDENCE; TESTING; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY; THRESHOLD DETECTORS; TIME DEPENDENCE
- Descriptors DEC
- ASIA; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CESIUM ISOTOPES; COBALT ISOTOPES; DATA; DEVELOPED COUNTRIES; DEVELOPING COUNTRIES; DOSEMETERS; DOSIMETRY; ELECTROMAGNETIC RADIATION; ENERGY RANGE; EUROPE; GREATER ANTILLES; INFORMATION; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IONIZING RADIATIONS; ISLANDS; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LATIN AMERICA; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; NEUTRON DETECTORS; NUCLEI; NUMERICAL DATA; ODD-EVEN NUCLEI; ODD-ODD NUCLEI; RADIATION DETECTORS; RADIATIONS; RADIOISOTOPES; SCANDINAVIA; WEST INDIES; WESTERN EUROPE; YEARS LIVING RADIOISOTOPES