Published December 12, 1994
| Version v1
Report
Open
Qualification test for the flexible receiver. Revision 2
Description
This document provides the test plan and procedures to certify and design verify the 42 double-prime and 4 double-prime-6 double-prime Flexible Receiver as a safety class 3 system. The Flexible Receiver will be used by projects W-151 and W-320 for removing equipment from tanks C-106 and AZ-101
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE95005214; NTIS; US Govt. Printing Office Dep.Files
26042180.pdf
Files
(3.8 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:9c34b1a8d32745f52a3ec9b5943b8350
|
3.8 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 151 p.
- Report number
- WHC-SD--W320-TIS-001-Rev.2
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26042180
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; S42: ENGINEERING;
- Descriptors DEI
- DESIGN; HANFORD RESERVATION; HIGH-LEVEL RADIOACTIVE WASTES; RADIOACTIVE WASTE MANAGEMENT; RADIOACTIVE WASTE STORAGE; REMOTE HANDLING EQUIPMENT; SAFETY; TANKS
- Descriptors DEC
- CONTAINERS; EQUIPMENT; MANAGEMENT; MATERIALS; MATERIALS HANDLING EQUIPMENT; NATIONAL ORGANIZATIONS; RADIOACTIVE MATERIALS; RADIOACTIVE WASTES; STORAGE; US DOE; US ORGANIZATIONS; WASTE MANAGEMENT; WASTE STORAGE; WASTES
Optional Information
- Contract/Grant/Project number
- Contract AC06-87RL10930
- Funding organization
- USDOE, Washington, DC (United States).