Supplemental design requirements document, Multifunction Waste Tank Facility, Project W-236A. Revision 1

Description

The Multi-Function Waste Tank Facility (MWTF) consists of four, nominal 1 million gallon, underground double-shell tanks, located in the 200-East area, and two tanks of the same capacity in the 200-West area. MWTF will provide environmentally safe storage capacity for wastes generated during remediation/retrieval activities of existing waste storage tanks. This document delineates in detail the information to be used for effective implementation of the Functional Design Criteria requirements

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95005466; NTIS; US Govt. Printing Office Dep.