Published August 2022 | Version v1
Journal article

The impact of slice thickness on diagnostic accuracy in digital breast tomosynthesis

  • 1. McMaster University, St Joseph's Healthcare, Department of Radiology, Hamilton, Ontario (Canada)

Description

To evaluate the effect of slice thickness on diagnostic accuracy in Digital Breast Tomosynthesis (DBT). Method: Two readers retrospectively interpreted 150 DBT (125 normal and 25 pathology-proven cancer) cases scanned between October 2017–November 2020. The DBT studies were randomised and reviewed independently by the two readers. DBT studies were reviewed using a standard protocol (1 mm slices, no overlap and synthetic 2D-mammography (SM)) and an experimental protocol (10 mm slabs, 5 mm overlap and SM). Any abnormality and BIRADS scores were recorded by each reader. Sensitivity, specificity, interobserver and intraobserver agreement were calculated (Cohen's Kappa κ). For diagnostic accuracy, the reference standard was histopathology or a normal mammogram at 2 years. Results: The sensitivity and specificity for reader 1 and 2 for cancer detection was reader 1 (97% and 79% for the standard protocol, 97% and 76% for the experimental protocol) and reader 2 (97% and 74% for both protocols). Reader 1 had 97.6% intraobserver agreement (κ .95) and reader 2 had 96.4% intraobserver agreement (κ .92) when assessing the standard and experimental protocols. There was 90.5% agreement between the readers for the standard protocol (κ .80). There was 90.9% agreement between the readers for the experimental protocol (κ .81). Of the 25 DBT studies with pathology-proven cancer, one cancer was missed by both readers using both protocols. Conclusion: The diagnostic accuracy was similar between the standard and experimental DBT protocols, demonstrating excellent interobserver and intraobserver agreement. This suggests 10-mm thick slabs can potentially replace 1-mm thin slices in the interpretation of DBT. (author)

Availability note (English)

Available from DOI: https://doi.org/10.1177/08465371211068200

Additional details

Identifiers

Publishing Information

Journal Title
Canadian Association of Radiologists Journal
Journal Volume
73
Journal Issue
3
Journal Page Range
p. 535-541
ISSN
0846-5371

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
54069814
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIGITAL SYSTEMS; MAMMARY GLANDS; NEOPLASMS; RADIOLOGY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; TOMOGRAPHY

Optional Information

Notes
18 refs.