Comparison of the deviation distribution in the doses administrated with and without mask in radiotherapeutic procedures
Creators
- 1. Departamento de Fisica e Matematica FFCLRP-USP, Av. Bandeirantes, 3900 CEP 14040-901, Cidade Universitari, Ribeirao Preto, SP (Brazil)
Description
In order to guarantee that the error limit in the dose administration is inside of the recommended limit by the ICRU (the ICRU recommends that the doses administrated in radiotherapy must be inside of a total deviation ± 5 %), the radiotherapy services are maintaining quality control programs and dosimetry which guarantee that the equipment yield or source should be known with precision. The Quality Control Programs foresee moreover the radiation beam calibration dosimetry, the In vivo dosimetry for obtaining a greater control of the administered doses. At present it counts on greater devices for maintaining the deviations inside this margin, and one of them is the u se of masks. The present work was carried out on a Siemens equipment model Gammatron S-80 (Co-60) in the Radiotherapy Service of the Sao Paulo University Hospital where teletherapy procedures are realized. (Author)
Files
30050727.pdf
Files
(98.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:a121c6406043821b53c9894d0038ea07
|
98.0 kB | Preview Download |
Additional details
Additional titles
- Original title (Spanish)
- Comparacion de la distribucion de los desvios en las dosis administradas con y sin mascara en procedimientos radioterapicos
Publishing Information
- Publisher
- Universidad Autonoma Metropolitana. Universidad Autonoma del Estado deMexico
- Imprint Place
- Mexico D.F. (Mexico)
- ISBN
- 968-835-419-8
- Imprint Title
- Proceedings of the 1st Ibero-Latin American and Caribbean Congress on Medical Physics. Mexico 98
- Imprint Pagination
- 283 p.
- Journal Page Range
- p. 199-201
- Report number
- INIS-MX--140
Conference
- Title
- 1. Ibero-Latin American and Caribbean Congress on Medical Physics
- Original Conference Title
- 1. Congreso Iberolatinoamericano y del Caribe de Fisica Medica
- Dates
- 22-25 Nov 1998
- Place
- Mexico, D.F. (Mexico)
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 30050727
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BRAZIL; COBALT 60; DOSIMETRY; ERRORS; HOSPITALS; ICRU; IN VIVO; MASKING; PATIENTS; RADIOTHERAPY; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BUILDINGS; COBALT ISOTOPES; DEVELOPING COUNTRIES; DOSEMETERS; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; INTERNATIONAL ORGANIZATIONS; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LATIN AMERICA; LUMINESCENT DOSEMETERS; MAMMALS; MAN; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; PRIMATES; RADIOISOTOPES; SOUTH AMERICA; THERAPY; VERTEBRATES; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- Imprint:Memorias. 1er Congreso Iberolatinoamericano y del Caribe de Fisica Medica. Mexico 98