Assessment of myocardial area at risk by technetium-99 sestamibi during coronary artery occlusion: Comparison between three tomographic methods of quantification

  • 1. Dept. of Nuclear Medicine, Ospedale Regionale, Varese (Italy)
  • 2. Div. of Cardiology, Ospedale Regionale, Varese (Italy)
  • 3. Dept. of Medical Physics, Pavia Univ., Varese (Italy)
  • 4. Nuclear Medicine Inst., Milan Univ. (Italy)

Description

The aim of this study was to compare three currently used quantitative methods of analysis of technetium-99m sestamibi images in patients with selective balloon-induced transmural ischaemia. The area at risk (AR) was assessed in 19 patients undergoing singlevessel percutaneous transluminal coronary angioplasty by injecting the 99mTc-sestamibi at the time of coronary artery occlusion during balloon inflation. After imaging, the patients were classified according to localization of the perfusion defect as having anteroseptal (group I, 11 patients) or posterolateral defects (group II, eight patients). The planimetric technique based on polar maps, proposed by Verani et al. (method A), the method described by Tamaki et al. (method B) and the technique validated by O'Connor et al. (method C) were tested. Three threshold values of 45%, 50% and 60% of the maximum left ventricular count were used to define the limits of the perfusion defect. The mean values of the AR calculated by the three techniques with the original cut-off level (method A=16.5%±12.9; method B=10.4%±7.6%; method C=29.6%±15.7%) were statistically different. There was no signicant difference between the mean values of the AR estimated by the three methods using the same cut-off levels. The use of 60% of the maximum left ventricular count provided the best correlation between the techniques. Nevertheless, a difference >10% between the values of AR assessed by the three methods was found in four subjects. There was no significant difference between the three methods in the evaluation of AR in the subjects of group I and group II. Reproducibility was good for all methods. It is concluded that the three methods of analysis of the AR by 99mTc-sestamibi SPET imaging showed comparable performance and good reproducibility using the same cut-off level. The location of perfusion defect does not affect the comparability of the three techniques. (orig./MG)

Additional details

Publishing Information

Journal Title
European Journal of Nuclear Medicine
Journal Volume
23
Journal Issue
1
Journal Page Range
p. 31-39.
ISSN
0340-6997
CODEN
EJNMD9