Published 2002 | Version v1
Miscellaneous

Optimization of screen-printed ruthenium dioxide electrodes for pH measurements

  • 1. Institute of Electronic Materials Technology, Warsaw (Poland)

Description

Optimization of disposable, screen-printed pH-sensors based on ruthenium dioxide is described in this paper. The electrodes were prepared with the use of thick-film technology. The pH-sensitive layers were deposited onto polyester foil. Polymer graphite paste containing ruthenium dioxide from 0% to 90% has been investigated. The dependence of the pH-sensitive layers related to ruthenium dioxide content is presented. The investigation proved that the electrodes containing 40-60% ruthenium dioxide exhibit linear high sensitivity (∼ 50 mV/pH) in the wide range of pH (2 - 11) as well as very good reproducibility. (author)

Part of:
Proceedings of 26. International Conference of International Microelectronics and Packaging Society - Poland Chapter IMAPS - Poland 2002

Additional details

Publishing Information

Imprint Title
Proceedings of 26. International Conference of International Microelectronics and Packaging Society - Poland Chapter IMAPS - Poland 2002
Imprint Pagination
244 p.
Journal Page Range
p. 87-90

Conference

Title
26. International Conference of International Microelectronics and Packaging Society - Poland Chapter IMAPS - Poland 2002
Dates
25-27 Sep 2002
Place
Warsaw (Poland)

Optional Information

Contract/Grant/Project number
KBN grant no. 7T09B 029 21
Notes