Published 1995 | Version v1
Miscellaneous

Development of a large scale PWR with hybrid safety systems

  • 1. Mitsubishi Heavy Industries, Ltd., Yokohama, Kanagawa (Japan)

Description

As described in this paper, it has been confirmed that the Hybrid Safety System can be applied for large scale PWR plant. This is because SG cooling system has been adopted as a passive decay heat removal purpose and did not use large or high pressure components for this purpose. By using the Hybrid Safety Systems, which include the new passive safety systems, the design has been significantly simplified, the reliability has been improved and the plant has became more economical. The conceptual designs have already been completed and the basic design work is now in progress. Efforts will be made to further improve the design, so that it can be applied to next generation of PWR plants. (author)

Part of:
ICONE-3: Proceedings of the 3rd JSME/ASME joint international conference on nuclear engineering. Volume 2

Additional details

Publishing Information

Imprint Title
ICONE-3: Proceedings of the 3rd JSME/ASME joint international conference on nuclear engineering. Volume 2
Imprint Pagination
512 p.
Journal Page Range
p. 733-738

Conference

Title
3. JSME/ASME joint international conference on nuclear engineering
Acronym
ICONE-3
Dates
23-27 Apr 1995
Place
Kyoto (Japan)

Optional Information

Notes
6 refs., 13 figs., 1 tab.