Detailed analysis for the cooling performance enhancement of a heat source under a thick plate
- 1. Department of Mechanical Engineering, Amirkabir University of Technology, Tehran 158754413 (Iran, Islamic Republic of)
- 2. Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 8415683111 (Iran, Islamic Republic of)
- 3. Department of Mechanical Engineering, Central Tehran Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of)
- 4. Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249 (United States)
Description
Highlights: • Attachment of a heat source to a thick plate is examined. • It is shown that the thick plate improves cooling performance. • Improvement of cooling performance is indicated by reducing the peak temperature. • It is proved that there is an optimal thickness of the thick plate. • Optimization is carried out based on numerical work via SIMPLEC algorithm. - Abstract: Maintaining the peak temperature of a heat source under an allowable level has always been a major concern for engineers engaged in the design of cooling systems for electronic equipment. The primary goal of this paper is to examine the advantages and/or disadvantages of placing a conductive thick plate as a heat transfer interface between a heat source and a cold flowing fluid. In such arrangement, the heat source is cooled under the thick plate instead of being cooled in direct contact with the cooling fluid. It is demonstrated that the thick plate can significantly improve the heat transfer between the heat source and the cooling fluid by way of conducting the heat current in an optimal manner. The two most attractive advantages of this method are that no additional pumping power and no extra heat transfer surface area, that is quite different from fins (extended surfaces). Unlike related archival papers in the literature, the present paper allows open spaces toward optimization. The objective is to minimize the maximum temperature, the 'hot spot'. Detailed analytical expressions are presented and a numerical analysis is carried out on the conservation equations based on the SIMPLEC algorithm. It is categorically proved that there exists an optimal thickness of the thick plate, which minimizes the peak temperature. Also, it is shown that the efficiency of the optimized plate on minimizing the target peak temperature depends upon the Reynolds number of the fluid flow and the material thermal conductivity
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2013.08.016Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2013.08.016;
- PII
- S0196-8904(13)00475-5;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 76
- Journal Page Range
- p. 691-700
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46004634
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ALGORITHMS; COOLING SYSTEMS; EFFICIENCY; ELECTRONIC EQUIPMENT; FINS; FLUID FLOW; HEAT SOURCES; HEAT TRANSFER; HOT SPOTS; NUMERICAL ANALYSIS; OPTIMIZATION; PLATES; REYNOLDS NUMBER; SURFACE AREA; THERMAL CONDUCTIVITY; THICKNESS
- Descriptors DEC
- DIMENSIONLESS NUMBERS; DIMENSIONS; ENERGY SYSTEMS; ENERGY TRANSFER; EQUIPMENT; MATHEMATICAL LOGIC; MATHEMATICS; PHYSICAL PROPERTIES; SURFACE PROPERTIES; THERMODYNAMIC PROPERTIES
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.