Published June 1977 | Version v1
Report Restricted

Reactor internals design/analysis for normal, upset, and faulted conditions

Description

The analytical procedures used by Babcock and Wilcox to demonstrate the structural integrity of the 205-FA reactor internals are described. Analytical results are presented and compared to ASME Code allowable limits for Normal, Upset, and Faulted conditions. The particular faulted condition considered is a simultaneous loss-of-coolant accident and safe shutdown earthquake. The operating basis earthquake is addressed as an Upset condition

Availability note (English)

MF available from INIS under the Report Number; Babcock and Wilcox, Lynchburg, VA.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
v p.
Report number
BAW--10060

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
9360426
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
EARTHQUAKES; LOSS OF COOLANT; MATHEMATICAL MODELS; PWR TYPE REACTORS; REACTOR COMPONENTS; SEISMIC EFFECTS; SPECIFICATIONS; STRESS ANALYSIS
Descriptors DEC
ACCIDENTS; REACTOR ACCIDENTS; REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS