Published September 1981 | Version v1
Journal article

γ-ray-source geometry corrections for use in gaseous radioactivity measurements

Creators

  • 1. General Electric Co., Pleasanton, CA (USA). Vallecitos Nuclear Center

Description

A new technique has been developed to determine geometric corrections for γ-ray counting for gaseous radioactivity measurements. A known amount of standardized non-volatile radioactivity, homogeneously mixed with vermiculite or any granular material with a bulk density of <approximately 0.15 g cm-3, is used as a mock standard for the gaseous activity contained in a sample container. An empirical equation is obtained to calculate correction factors for the gaseous radioactivities contained in a 14.1-ml boiling water reactor (BWR) off-gas sample-vial and counted on Ge(Li) detectors. Experimental data are also reported for the corrections for gaseous radioactivities relative to the liquid standard contained in the 14.1-ml glass vial. (author)

Additional details

Publishing Information

Journal Title
Int. J. Appl. Radiat. Isot.
Journal Volume
32
Journal Issue
9
Series
Int. J. Appl. Radiat. Isot.
Journal Page Range
657-663
ISSN
0020-708X