Published 2000 | Version v1
Book

Experience with chemical control in the feed water and steam generators at MAPS

  • 1. Madras Atomic Power Station, Kalpakkam (India)

Description

Sea water is used for cooling the main Condensers and the Process Sea Water Heat Exchangers at MAPS. In other PHWRs in India Lake/River water is used for cooling main condensers. Morpholine is used as an alkalising agent in the feed water and condensate system for maintaining the pH in the range 8.5-9.2 in all the Indian PHWRs. During the initial stages of operation of both the Units at MAPS, congruent phosphate control was adopted in the Steam Generators whenever condenser tube leak occurred to maintain the pH and to remove the scale forming ions by blowdown. As this treatment has not been found satisfactory, Condensate Polishing Plants were retrofitted in both the units at a later stage. The experience gained and the problems encountered in the operation of Condensate Polishing Plant with the imported and indigenous macroporous resins in the maintenance of chemical parameters in the Steam Generators are highlighted in this paper. (author)

Part of:
Proceedings of the national symposium on water and steam chemistry in power plants and industrial units

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of the national symposium on water and steam chemistry in power plants and industrial units
Imprint Pagination
680 p.
Journal Page Range
p. 632-637

Conference

Title
national symposium on water and steam chemistry in power plants and industrial units
Acronym
SWASCH-2000
Dates
23-25 Feb 2000
Place
Mumbai (India)

Optional Information

Notes
6 refs., 3 tabs.