Published 1989 | Version v1
Miscellaneous

Deaerator transient at Bruce NGS 'B' Unit 8

  • 1. Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A

Description

On April 25, 1987 during a planned 800 MW(e) load rejection test on Unit 8, a violent transient occurred in the deaerator/deaerator storage tank which caused the 500 ton vessel-piping network to tear away from its supports and move approximately three inches in an axial direction. Considerable effort was brought to bear and within one week the unit was returned to service. This paper describes the physical nature of the event and the role of the Bruce NGS 'B' training simulator in developing and testing control modifications to prevent its recurrence. (author). 4 refs., 6 figs

Part of:
Proceedings of the 29th annual conference of the Canadian Nuclear Association and 10th annual conference of the Canadian Nuclear Society. V. 1-3

Additional details

Publishing Information

ISBN
0-919307-39-6; 0-919784-17-8
Imprint Title
Proceedings of the 29th annual conference of the Canadian Nuclear Association and 10th annual conference of the Canadian Nuclear Society. V. 1-3
Imprint Pagination
3 v. [1200 p.].
Journal Page Range
v. 3 p. 16.36-16.42.
ISSN
0706-1293; 0227-1907
Report number
INIS-mf--14668

Conference

Title
10. annual conference of the Canadian Nuclear Society.
Dates
4-7 Jun 1989.
Place
Ottawa, ON (Canada).

Optional Information