Published April 2002
| Version v1
Journal article
Elemental content in ground and soluble/instant coffee
- 1. Universidad Autonoma de Zacatecas (Mexico). Centro Regional de Estudios Nucleares
- 2. Texas Univ., Austin, TX (United States). Nuclear Engineering Teaching Lab.
Description
The concentration of thirty-four elements in twelve coffee brands has been measured using instrumental neutron activation analysis. The samples investigated included four brands of commercially available ground coffee and eight brands of soluble/instant coffee. The elements measured were Al, As, Ba, Ca, Ce, Co, Cr, Cs, Dy, Eu, Fe, Gd, Hf, K, La, Lu, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, Ti, Tm, U, V, Yb and Zn. Twenty four elements were found to be below the detection limit in one or more samples. These elements were Ce, Cr, Fe, V, As, Eu, Ba, Dy, Gd, Hf, La, Lu, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, Ti, Yb, Tm, and U. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Radioanalytical and Nuclear Chemistry
- Journal Volume
- 252
- Journal Issue
- 1
- Journal Page Range
- p. 75-80
- ISSN
- 0236-5731
- CODEN
- JRNCDM
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 33030311
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- BEVERAGES; COFFEE BEANS; DIET; ELEMENT ABUNDANCE; MULTI-ELEMENT ANALYSIS; NEUTRON ACTIVATION ANALYSIS
- Descriptors DEC
- ABUNDANCE; ACTIVATION ANALYSIS; CHEMICAL ANALYSIS; FOOD; NONDESTRUCTIVE ANALYSIS; SEEDS
Optional Information
- Notes
- 16 refs.