Published April 2002 | Version v1
Journal article

Elemental content in ground and soluble/instant coffee

  • 1. Universidad Autonoma de Zacatecas (Mexico). Centro Regional de Estudios Nucleares
  • 2. Texas Univ., Austin, TX (United States). Nuclear Engineering Teaching Lab.

Description

The concentration of thirty-four elements in twelve coffee brands has been measured using instrumental neutron activation analysis. The samples investigated included four brands of commercially available ground coffee and eight brands of soluble/instant coffee. The elements measured were Al, As, Ba, Ca, Ce, Co, Cr, Cs, Dy, Eu, Fe, Gd, Hf, K, La, Lu, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, Ti, Tm, U, V, Yb and Zn. Twenty four elements were found to be below the detection limit in one or more samples. These elements were Ce, Cr, Fe, V, As, Eu, Ba, Dy, Gd, Hf, La, Lu, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, Ti, Yb, Tm, and U. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
252
Journal Issue
1
Journal Page Range
p. 75-80
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
16 refs.