Published July 2009 | Version v1
Journal article

Evaluation of all dose components in the LVR-15 reactor epithermal neutron beam using Fricke gel dosimeter layers

  • 1. National Institute of Nuclear Physics (INFN) Section of Milano, via Celoria 16, 20133 Milan (Italy)
  • 2. Department of Physics, University of Milan, via Celoria 16, 20133 Milan (Italy)
  • 3. Department of Reactor Physics, Nuclear Research Institute Rez, Husinec-Rez 130, 25068 Rez (Czech Republic)

Description

Fricke gel dosimeters in the form of layers are suitable to reconstruct bidimensional distributions of the absorbed dose; in accordance with their chemical composition and applying suitably developed algorithms, they can provide dose images of the different radiation components in a BNCT field. After the description of the applied method, this work presents the results obtained at the epithermal column of the BNCT facility at the NRI in Rez (CZ). The measured dose distributions are shown in comparison with data taken by means of other dosimeters thermoluminescence dosimeters (TLDs) and with calculations carried out with the Monte Carlo code MCNP5. The agreement with the results obtained by means of the different techniques is satisfying.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2009.03.049

Additional details

Identifiers

DOI
10.1016/j.apradiso.2009.03.049;
PII
S0969-8043(09)00283-8;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
67
Journal Issue
7-8,suppl
Journal Page Range
p. S199-S201
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
A new option against cancer
Acronym
13. international congress on neutron capture therapy BNCT
Dates
2-8 Nov 2008
Place
Florence (Italy)

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.