Cost benefit justification of nuclear plant reliability improvement
Creators
- 1. Faculty of Engineering, Qatar Univ., P.O. Box 2713, Doha
Description
The design of the secondary steam loop of the nuclear power plant has a significant effect on the reliability of the plant. Moreover, the necessity to cool a reactor safely has increased the reliability demanded from the system. The rapidly rising construction costs and fuel prices in recent years have stimulated a great deal in optimizing the productivity of a nuclear power plant through reliability improvement of the secondary steamloop and the reactor cooling system. A method for evaluating the reliability of steam loop and cooling system of a nuclear power plant is presented. The method utilizes the cut-set technique. The developed method can be easily used to show to what extent the overall reliability of the nuclear plant is affected by the possible failures in the steam and cooling subsystem. A model for calculating the increase in the nuclear plant productivity resulting from a proposed improvement in the two subsystems reliability is discussed. The model takes into account the capital cost of spare parts for several components, replacement energy, operating and maintenance costs
Additional details
Publishing Information
- Publisher
- Hemisphere Publishing.
- Imprint Place
- New York, NY (USA)
- ISBN
- 0-89116-661-0
- Imprint Title
- Alternative energy sources VII
- Journal Page Range
- p. 461-470.
Conference
- Title
- 7. Miami international conference on alternative energy sources.
- Dates
- 9-11 Dec 1985.
- Place
- Miami Beach, FL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18090597
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COST BENEFIT ANALYSIS; FAILURE MODE ANALYSIS; MATHEMATICAL MODELS; NUCLEAR POWER PLANTS; OPTIMIZATION; PERFORMANCE; POWER REACTORS; PRODUCTION; REACTOR COOLING SYSTEMS; REACTOR MAINTENANCE; REACTOR OPERATION; REACTOR SAFETY; RELIABILITY; SECONDARY COOLANT CIRCUITS; STEAM
- Descriptors DEC
- COOLING SYSTEMS; ECONOMIC ANALYSIS; MAINTENANCE; NUCLEAR FACILITIES; OPERATION; POWER PLANTS; REACTOR COMPONENTS; REACTORS; SAFETY; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; THERMAL POWER PLANTS