Published January 2003
| Version v1
Journal article
Optimal concentration of contrast material in multidetector-row CT of the thorax
Creators
- 1. Osaka Medical Coll., Takatsuki (Japan)
Description
To assess the optimal concentration of iodinated contrast for multidetector-row CT (MDCT) of the thorax, 196 examinations were prospectively performed after intravenously administering iohexol 240, 300 or 350 mgI/ml dose of 100 ml. In visual evaluation, iohexol 300 and 350 mgI/ml revealed better imaging qualities than 240 mgI/ml material. There was no significant difference between 300 and 350 mgI/ml iohexol. In the patients weighing less than 50 kg, even imaging quality obtained with iohexol 240 mgI/ml was not significantly different from that of the others. (author)
Additional details
Publishing Information
- Journal Title
- Rinsho Hoshasen
- Journal Volume
- 48
- Journal Issue
- 1
- Journal Page Range
- p. 67-72
- ISSN
- 0009-9252
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 34034681
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- AORTA; CARCINOMAS; CAT SCANNING; CHEST; IMAGES; IOHEXOL; LUNGS; VEINS