Published 1985 | Version v1
Report Restricted

Personnel neutron dosimetry using TLD elements at PNC

  • 1. Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

Description

The evaluation method of neutron dose equivalent was studied on the basis of the albedo type neutron dosimetory to design the personnel dosimeter. The dosimeter was composed of three 6Li210B4O7(Cu) TL elements and one 7Li211B4O7(Cu) element. The equations for assessing thermal, epithermal and fast neutron dose equivalents were derived by 252Cf, 241Am-Be and PuO2 neutron sources. The minimum detectable amount of 6Li210B4O7(Cu) element to thermal neutron was 0.02 m rem. The neutron dose equivalent and the gamma one were evaluated separately within about 20 % error in the mixed radiation field. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Proceedings of the conference on 'methods of measurement and evaluation of personnel neutron exposure'
Imprint Pagination
89 p.
Journal Page Range
p. 28-33.
Report number
KURRI-TR--269

Conference

Title
Methods of measurement and evaluation of personnel neutron exposure.
Dates
27 Jul 1984.
Place
Kumatori, Osaka (Japan).