Published May 2011
| Version v1
Miscellaneous
Analysis the PORV accident for the Kori no.2 using SPACE code
- 1. Korea Electric Power Research Institute, Daejeon (Korea, Republic of)
Description
Fail Low signal is generated by the malfunction of control pressure channel at Kori no.2 in 1995. Consequently, the reactor is stopped by over temperature error signal follow a rapid decompression. Safety injection system is down as the pressurizer water level reach to 92%, the reactor coolant pumps of the flow path 'B' is down. And then, RCS cooling started using the RHRS, but RCP of the flow path 'A' was also stopped. By the site inspection, it confirmed in a driver of the pressurizer spray valve PCV-655B and a valve connection bar are breaking. In this study analyze the accident using the SPACE code
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2011 spring meeting of the KNS
- Dates
- 26-27 May 2011
- Place
- Taebaek (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42099186
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- KORI-2 REACTOR; PUMPS; PWR TYPE REACTORS; S CODES; SAFETY INJECTION; VALVES
- Descriptors DEC
- COMPUTER CODES; CONTROL EQUIPMENT; ENRICHED URANIUM REACTORS; EQUIPMENT; FLOW REGULATORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 6 refs, 8 figs