Matching Ge detector element geometry to sample size and shape: One does not fit all exclamation point

  • 1. EG and G ORTEC (United States)

Description

For 25 yr, coaxial germanium detector performance has been specified using the methods and values specified in Ref. 1. These specifications are the full-width at half-maximum (FWHM), FW.1M, FW.02M, peak-to-Compton ratio, and relative efficiency. All of these measurements are made with a 60Co source 25 cm from the cryostat endcap and centered on the axis of the detector. These measurements are easy to reproduce, both because they are simple to set up and use a common source. These standard tests have been useful in guiding the user to an appropriate detector choice for the intended measurement. Most users of germanium gamma-ray detectors do not make measurements in this simple geometry. Germanium detector manufacturers have worked over the years to make detectors with better resolution, better peak-to-Compton ratios, and higher efficiency--but all based on measurements using the IEEE standard. Advances in germanium crystal growth techniques have made it relatively easy to provide detector elements of different shapes and sizes. Many of these different shapes and sizes can give better results for a specific application than other shapes and sizes. But, the detector specifications must be changed to correspond to the actual application. Both the expected values and the actual parameters to be specified should be changed. In many cases, detection efficiency, peak shape, and minimum detectable limit for a particular detector/sample combination are valuable specifications of detector performance. For other situations, other parameters are important, such as peak shape as a function of count rate. In this work, different sample geometries were considered. The results show the variation in efficiency with energy for all of these sample and detector geometries. The point source at 25 cm from the endcap measurement allows the results to be compared with the currently given IEEE criteria. The best sample/detector configuration for a specific measurement requires more and different specifications than the IEEE standard

Additional details

Publishing Information

Journal Title
Transactions of the American Nuclear Society
Journal Volume
79
Journal Page Range
p. 104
ISSN
0003-018X
CODEN
TANSAO

Conference

Title
American Nuclear Society winter meeting
Dates
15-19 Nov 1998
Place
Washington, DC (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
30011188
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
GAMMA DETECTION; GE SEMICONDUCTOR DETECTORS; GEOMETRY; PERFORMANCE TESTING; SHAPE; SIZE; SPECIFICATIONS; STANDARDS
Descriptors DEC
DETECTION; MATHEMATICS; MEASURING INSTRUMENTS; RADIATION DETECTION; RADIATION DETECTORS; SEMICONDUCTOR DETECTORS; TESTING

Optional Information

Secondary number(s)
CONF-981106--